Filters
Dissolved oxygen range
▾
0.0 to 20.0 mg / L (or ppm)
0.0 to 20.0 mg/L (or ppm)
0.0 - 20.0 mg / L (or ppm)
Dissolved oxygen accuracy
▾
± 0.5 mg / L
± 0.2 mg / L
± 0.5 mg/L
Resolution
▾
0.1 mg / L
0.01 mg / L
0.001, 0.01, 0.1, 1
Calibration points
▾
1 - 2 points
2 to 5 points
2 points
1-3 points
1-5 points
1 - 3 points
1 point
1 - 5 points
Sensor type
▾
Polarographic DO probe
Platinum sensor
Polarographic dissolved oxygen probe
Temperature compensation range
▾
0 to 40 °C, 32 to 104 °F
0 to 50 °C, 32 to 122 °F
0 to 50 °C
0 °C to 40 °C, 32 °F to 104 °F
0 °C to 60 °C, 32 °F to 140 °F
0 °C to 60 °C, Automatic
0 to 40 °C, 32 °F to 104 °F
0 to 50 °C, 32 °F to 122 °F, Automatic
0 - 50 °C
Barometric pressure correction
▾
60.0 to 112.5 kPa, 450 to 850 mmHg
Salinity correction
▾
0 - 35 g / L
0 - 50 g / L
0 - 35 g/L
0 to 50 g / L
% of saturation of oxygen range
▾
0.0 to 200.0 %
% of saturation of oxygen accuracy
▾
± 10 % F.S.
± 2.0 % F.S.
% of saturation of oxygen resolution
▾
0.001
0.1, 1 %
System menu
▾
Allows setting of 6 parameters
Allows setting of 9 parameters
Data hold function
▾
Manual or automatic endpoint detection
Manual or automatic endpoint detection
Manual or automatic
Manual
Manual or Automatic
Power off
▾
Manual or automatic (180 minutes)
Manual or automatic (10, 20, 30 minutes)
Manual or automatic (10,20,30 minutes)
Manual or automatic (180 minutes after last key is pressed)
Manual or automatic (8 minutes after last key is pressed)
Manual or automatic (8 minute after last key is pressed)
Reset function
▾
Yes
Display
▾
Backlit LCD (135 × 75 mm)
Backlit LCD (130 × 110 mm)
LCD (130 × 110 mm)
LCD (315 × 75 mm)
LCD
LCD (320 × 240)
LCD screen
Connector
▾
6 pin mini plug
BNC
6 - pin mini plug
6 pin
4-pin mini plug
Power
▾
DC 9 V, use of SC adapter, AC 220 V / 50 Hz
DC 5 V, use of AC adapter, AC 220 V / 50 Hz
DC 5 V, using AC adapter, AC 220 V / 50 Hz
3 × 1.5 V “AA” batteries
DC 6 V / 400 mA power adapter, AC 220 V / 50 Hz
DC 6 V / 400 mA power adapter, AC 220 V / 50Hz
DC9V, Ac adapter, AC220V /50Hz
DC9V, AC adapter, AC220V/50Hz
DC5V using AC adapter, AC220V /50 Hz
3 × 1.5 V “G134” batteries
2 × 1.5V “AAA” batteries
2 × 1.5 V AAA batteries
3 × 1.5 V “G13A”
2 × 1.5 V “AAA”
1 x 9 V / 800 mA battery
3 x 1.5 V “AA” batteries
9 V / 800 mA battery
4.5 V “AA batteries or DC 5 V power adapter
Dimension (L × W × H)
▾
210 × 205 × 75 mm
210 × 188 × 60 mm
170 × 85 × 30 mm
185 × 88 × 32 mm
Weight
▾
1.5 kg
100 g
300 g
2.5 kg
Memory
▾
Stores up to 50 data sets
Stores up to 500 sets of data
Stores up to 48 sets of data
Stores up to 500 data sets
Stores up to 20 sets data
Stability conditions
▾
Low or high
Calibration due
▾
0 to 31 days
Ion measurement range
▾
Cl range: 5 × 10<sup>6</sup> - 1 M, 1.8 - 35500 ppm
F range: 1 × 10<sup>6</sup>M – saturation, 0.02 ppm to saturation
Na range: 1 × 10<sup>5</sup> - 1 M, 0.1 - 23000 ppm
Ca range: 5 × 10<sup>7</sup> - 1 M, 0.02 - 4000 ppm
Br range: 5 × 10<sup>6</sup> - 1 M, 0.4 - 79900 ppm
NH<sub>4</sub> range: 5 × 10<sup>6</sup> – 1 M, 0.1 – 18000 ppm
NH<sub>3</sub> range: 1 × 10<sup>6</sup> - 1 M, 0.02 - 17000 ppm
Cn range: 5 × 10<sup>6</sup> – 0.01 M, 0.2 – 260 ppm
Ag range: 1 × 10<sup>7</sup> - 1 M, 0.01 - 107900 ppm
K range: 1×10<sup>6</sup> - 1M, 0.04 -39000 ppm
S range: 1×10<sup>7</sup> - 1M, 0.003-32100 ppm
Pb range: 1×10<sup>8</sup> – 0.1M, 0.2-20700 ppm
I range: 1×10<sup>8</sup>- 1M, 0.06 -127000 ppm
Cu range: 1×10<sup>8</sup> - 1M, 0.06-6400 ppm
Cd range: 1×10<sup>6</sup>– 1M, 0.01-11200 ppm
Ion measurement accuracy
▾
± 0.5 % F.S.
± 1 % F.S.
Calibration solutions
▾
0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18)
USA (pH 4.0/7.00/10.01)
USA, NIST, DIN or user defined
84 µS/cm, 1413 µS/cm, 12.88 mS/cm
1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
71.8 ppm
744.7 ppm
7447 ppm
100 ppm, 1000 ppm, 10 ppt
USA (pH 4.01 / 7.00 / 10.01),
USA (pH 4.01 / 7.00 / 10.01 / 12.45), NIST(pH 1.68 / 4.01 / 6.86 / 9.18 / 12.45), DIN (pH 1.09 / 4.65 / 6.79 / 9.23 / 12.75) or user defined
mV range
▾
(-1999.9) to 1999.9 mV
-1999 to 1999 mV
-1000 to 1000 mV
(-1999) to 1999 mV
mV accuracy
▾
± 0.2 mV
±10mV
±1mV
± 1 mV
mV resolution
▾
0.1 mV
1 mV
0.1, 1 mV
Temperature measurement range
▾
0 to 105 °C, 32 to 221 °F
Temperature accuracy
▾
± 0.5 °C, ± 0.9 °F
± 0.5 °C
± 1°
±1°C
± 1 °C
Temperature resolution
▾
0.1°C
0.1 °C
1°C
Temperature compensation
▾
0 to 100 °C, 32 to 212 °F
0 to 100°C
0 to 100°C, 32 to 212°F
0 °C - 50 °C
0 °C - 50 °C, Automatic
0 °C - 60 °C, Automatic
0 to 100 °C, 32 to 212 °F, Manual or Automatic
Compensation mode
▾
Manual or automatic
Manual
Stability condition
▾
Low or high
Output
▾
USB communication interface
Water hardness range
▾
0.05 mmol / L -0.2 mol / L <br/> (CaCO<sub>3</sub>) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L<br/> (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
0.05 mmol / L - 0.2 mol / L<br/> (CaCO<sub>3</sub>) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L<br/> (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy
▾
± 1 % F.S.
Calibration solution
▾
0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/L
USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18)
0.001, 0.01, 0.1 mmol / L, 0.001, 0.01, 0.1 mol / L
Temperature range
▾
0 - 105 °C
0 to 105 °C, 32 to 221 °F
0 to 100°C, 32 to 212°F
0 to 105°C, 32 to 221°F
Calibration range
▾
Measured value ± 10 °C
Battery life
▾
Approximately 150 hours
200 hours
Approximately 200 hours
About 150 hours
About 200 hours
Conductivity measurement range
▾
0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
1.0 to 199.9 µS/cm
10 to 1999 µS/cm
0.1 to 19.99 mS/cm
Conductivity accuracy
▾
± 1 % F.S.
Conductivity resolution
▾
0.01, 0.1, 1
Conductivity calibration solutions
▾
10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm
146.5 µS/cm
1413 µS/cm
12.88 mS/cm
Conductivity calibration points
▾
1 - 3 points
1 point
Temperature compensation range & mode
▾
Manual, 0 to 100 °C , 32 to 212 °F
Manual or automatic, 0 to 100 °C , 32 to 212 °F
Temperature coefficient
▾
0.0 to 10.0 % per °C
2 % per °C
Cell constant
▾
K= 0.1, 1, 10 or User-defined
K=1
pH measurement range
▾
0.00 to 14.00 pH
-1.00 to 15.00 pH
-2.000 to 20.000 pH
0.0 - 14.00 pH
pH range: (-1.00) to 15.00 pH
pH accuracy
▾
± 0.05 pH
± 0.01 pH
± 0.002 pH
pH resolution
▾
0.01 pH
0.1, 0.01, 0.001 pH
Dimension (L*W*H)
▾
210×205×65 mm
210×205×75 mm
210×188×60 mm
Hold function
▾
Manual or automatic endpoint detection
Manual
ORP measurement range
▾
-1999.9 to 1999.9 mV
(-999) to 999 mV
ORP accuracy
▾
±0.2 mV
± 2 mV
ORP calibration points
▾
1 point
1 point (only for relative mV mode)
ORP calibration range
▾
±200 mV
ORP calibration solutions
▾
mV & relative mV
memory
▾
Stores up to 500 data sets
COD
▾
a:11:{s:23:"COD determination range";s:16:"2 to 10000 mg/ L";s:24:"COD measurement accuracy";s:61:"COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %";s:27:"COD minimum detection limit";s:9:"0.1 mg/ L";s:20:"COD measurement time";s:10:"20 minutes";s:17:"COD repeatability";s:10:"≤ ± 5 %";s:41:"Processing sample number per batch";s:0:"";s:44:"Consumables for colorimetric COD measurement";s:30:"Colorimetric tubes and Cuvette";s:33:"COD reactor digestion temperature";s:14:"165 ± 0.5°C";s:26:"COD reactor digestion time";s:6:"10 min";s:33:"COD reactor time setting switches";s:5:"3 pcs";s:26:"Anti-chlorine interference";s:27:"(Cl) < 1000 mg/ L No effect";}
a:11:{s:23:"COD determination range";s:15:"5 to 5000 mg/ L";s:24:"COD measurement accuracy";s:61:"COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %";s:27:"COD minimum detection limit";s:9:"0.1 mg/ L";s:20:"COD measurement time";s:10:"20 minutes";s:17:"COD repeatability";s:10:"≤ ± 5 %";s:41:"Processing sample number per batch";s:6:"12 pcs";s:44:"Consumables for colorimetric COD measurement";s:30:"Colorimetric tubes and Cuvette";s:33:"COD reactor digestion temperature";s:14:"165 ± 0.5°C";s:26:"COD reactor digestion time";s:6:"10 min";s:33:"COD reactor time setting switches";s:5:"3 pcs";s:26:"Anti-chlorine interference";s:27:"(Cl) < 1000 mg/ L No effect";}
Ammonia nitrogen
▾
a:8:{s:36:"Ammonia nitrogen determination range";s:16:"0.02 to 60 mg/ L";s:37:"Ammonia nitrogen measurement accuracy";s:11:"≤ ± 10 %";s:40:"Ammonia nitrogen minimum detection limit";s:10:"0.01 mg/ L";s:33:"Ammonia nitrogen measurement time";s:16:"10 to 15 minutes";s:30:"Ammonia nitrogen repeatability";s:10:"≤ ± 5 %";s:41:"Processing sample number per batch";s:0:"";s:57:"Consumables for colorimetric ammonia nitrogen measurement";s:30:"Colorimetric tubes and Cuvette";s:46:"Ammonia nitrogen reactor time setting switches";s:5:"3 pcs";}
a:8:{s:36:"Ammonia nitrogen determination range";s:16:"0.02 to 30 mg/ L";s:37:"Ammonia nitrogen measurement accuracy";s:11:"≤ ± 10 %";s:40:"Ammonia nitrogen minimum detection limit";s:10:"0.01 mg/ L";s:33:"Ammonia nitrogen measurement time";s:16:"10 to 15 minutes";s:30:"Ammonia nitrogen repeatability";s:10:"≤ ± 5 %";s:41:"Processing sample number per batch";s:6:"20 pcs";s:57:"Consumables for colorimetric ammonia nitrogen measurement";s:30:"Colorimetric tubes and Cuvette";s:46:"Ammonia nitrogen reactor time setting switches";s:5:"3 pcs";}
Total phosphorous
▾
a:10:{s:37:"Total phosphorous determination range";s:17:"0.002 to 20 mg/ L";s:56:"Total phosphorous total phosphorous measurement accuracy";s:10:"≤ ± 5 %";s:41:"Total phosphorous minimum detection limit";s:11:"0.001 mg/ L";s:34:"Total phosphorous measurement time";s:16:"35 to 50 minutes";s:31:"Total phosphorous repeatability";s:10:"≤ ± 5 %";s:41:"Processing sample number per batch";s:0:"";s:58:"Consumables for colorimetric total phosphorous measurement";s:30:"Colorimetric tubes and Cuvette";s:47:"Total phosphorous reactor digestion temperature";s:14:"120 ± 0.5°C";s:40:"Total phosphorous reactor digestion time";s:6:"30 min";s:47:"Total phosphorous reactor time setting switches";s:5:"3 pcs";}
a:10:{s:37:"Total phosphorous determination range";s:17:"0.002 to 10 mg/ L";s:56:"Total phosphorous total phosphorous measurement accuracy";s:10:"≤ ± 5 %";s:41:"Total phosphorous minimum detection limit";s:11:"0.001 mg/ L";s:34:"Total phosphorous measurement time";s:16:"35 to 50 minutes";s:31:"Total phosphorous repeatability";s:10:"≤ ± 5 %";s:41:"Processing sample number per batch";s:6:"12 pcs";s:58:"Consumables for colorimetric total phosphorous measurement";s:30:"Colorimetric tubes and Cuvette";s:47:"Total phosphorous reactor digestion temperature";s:14:"120 ± 0.5°C";s:40:"Total phosphorous reactor digestion time";s:6:"30 min";s:47:"Total phosphorous reactor time setting switches";s:5:"3 pcs";}
Turbidity
▾
a:6:{s:29:"Turbidity determination range";s:14:"0.5 to 400 NTU";s:30:"Turbidity measurement accuracy";s:10:"≤ ± 5 %";s:34:"Turbidity minimum detection limit";s:7:"0.1 NTU";s:26:"Turbidity measurement time";s:8:"1 minute";s:23:"Turbidity repeatability";s:10:"≤ ± 5 %";s:50:"Consumables for colorimetric turbidity measurement";s:20:"Colorimetric Cuvette";}
Light source life
▾
100000 hours
Optical stability
▾
≤ 0.001 A/ 10 min
No. of curves
▾
166
56
Storage data
▾
12000
Interface
▾
USB
Power supply
▾
AC 200 V
AC 220 V, 50 Hz
3 × 1.5 V “AA batteries or DC 5 V power adapter
Dimension
▾
550 × 300 × 250 mm
450 × 300 × 250 mm
370 × 260 × 150 mm
400 × 300 × 250 mm
Gross Weight
▾
21 kg
18 kg
Type of conductivity
▾
Low range conductivity
Mid-range conductivity
High range conductivity
Normalization temperature
▾
25 °C
Dimension (L*dia.)
▾
185 × 40 mm
175 × 40 mm
% of saturation of oxygen
▾
0.0 to 200.0%
% Saturation of oxygen accuracy
▾
± 10 % F.S.
Dimension (L × Dia.)
▾
175 × 40 mm
185 × 40 mm
ORP resolution
▾
1 mV
Salinity measurement range
▾
0.00 to 10.00 ppt
0.00 to 80.00 ppt
Salinity accuracy
▾
± 1 % F.S
Conductivity range
▾
0 - 20.00, 200.0, 2000 µS/cm, 20.00 mS/cm
0 - 200.0 µS/cm, 100 - 2000 µS/cm, 20.00 mS/cm
Conductivity accuracy
▾
± 1 % F.S
TDS range
▾
0.5 - 100.0 ppm
5 - 1000 ppm
0.05 - 10.00 ppt
0 - 20 ppt
TDS accuracy
▾
± 1 % F.S.
TDS factor
▾
0.4 to 1.0 (default 0.5)
0.1 to 1.0 (default 0.5)
TDS type range
▾
Low range TDS
Mid-range TDS
High range TDS
Type of sensor
▾
Platinum sensor
Operating temperature
▾
0 °C - 60 °C, 32 °F - 140 °F
0 °C to 60 °C, 32 °F to 140 °F
5 to 40°C
Dimension (L × dia.)
▾
185 × 40 mm
Shape of electrode
▾
Round glass pH electrode
Flat pH electrode
Long distance planar pH electrode
pH measurement accuracy
▾
± 0.1 pH
± 0.01 pH
Calibration point
▾
2 points
1 - 3 points
Nil
4
5
6
7
Shutdown mode
▾
Manual or automatic ( 8 minutes without key operations)
Dimension (length × diameter)
▾
185 × 40 mm
Power type
▾
3 × 1.5 V G13A button battery 3
2 × 1.5 V AAA batteries
Dimension (L x W x H)
▾
185 × 88 × 32 mm
170 × 85 × 30 mm
Stability connector
▾
Low or high
Measuring range (NTU)
▾
0 to 200
0 to 100, 0 to 200
0 to 100, 100 to 400
0 to 100, 100 to 500
0 to 100, 100 to 800
0 to 100, 100 to 1000
0 to 100, 100 to 400
0 to 100, 100 to 1000
Minimum readout value (NTU)
▾
0.1
0.01, 0.1
Sample volume
▾
5 to 10 ml
Principle method
▾
90° scattered light
Working temperature
▾
5 to 40°C
Light source
▾
Infrared-emitting diode (850 nm λ)
Detector
▾
Silicon photodiode
Error value
▾
± 6 % (± 2 % F.S)
Zero drift
▾
± 0.5 % F.S.
Reset functions
▾
Yes
Power batteries
▾
DC 1.5 V, 5 AA alkaline batteries
pH mode
▾
a:4:{s:20:"pH measurement range";s:21:"(-2.000) to 20.000 pH";s:11:"pH accuracy";s:11:"± 0.002 pH";s:21:"pH calibration points";s:12:"1 - 5 points";s:24:"pH calibration solutions";s:30:"USA, NIST, DIN or user defined";}
ORP measurement
▾
a:4:{s:21:"ORP measurement range";s:20:"-1999.9 to 1999.9 mV";s:12:"ORP accuracy";s:8:"±0.2 mV";s:22:"ORP calibration points";s:7:"1 point";s:25:"ORP calibration solutions";s:16:"mV & relative mV";}
Ion measurement
▾
a:4:{s:21:"Ion measurement range";s:27:"0 to 19999 ppm, mg/L, mol/L";s:13:"Ion accuracy";s:50:"± 0.5 % F.S. (monovalent), ± 1 % F.S. (divalent)";s:22:"Ion calibration points";s:12:"2 - 5 points";s:25:"Ion calibration solutions";s:58:"0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/L, mg/L";}
a:4:{s:21:"Ion measurement range";s:0:"";s:13:"Ion accuracy";s:0:"";s:22:"Ion calibration points";s:0:"";s:25:"Ion calibration solutions";s:0:"";}
Conductivity measurement
▾
a:8:{s:30:"Conductivity measurement range";s:53:"0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm";s:22:"Conductivity accuracy";s:13:"± 0.5 % F.S.";s:31:"Conductivity calibration points";s:12:"1 - 5 points";s:34:"Conductivity calibration solutions";s:67:"10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm";s:23:"Temperature coefficient";s:19:"0.0 to 10.0 % / °C";s:18:"Compensation modes";s:19:"Linear or pre water";s:13:"Cell constant";s:30:"K = 0.1, 1, 10 or user-defined";s:25:"Normalization temperature";s:16:"20 °C or 25 °C";}
a:8:{s:30:"Conductivity measurement range";s:0:"";s:22:"Conductivity accuracy";s:0:"";s:31:"Conductivity calibration points";s:0:"";s:34:"Conductivity calibration solutions";s:0:"";s:23:"Temperature coefficient";s:0:"";s:18:"Compensation modes";s:0:"";s:13:"Cell constant";s:0:"";s:25:"Normalization temperature";s:0:"";}
TDS measurement
▾
a:3:{s:9:"TDS range";s:58:"0 to 100 ppt. (max. 200 ppt., depending on factor setting)";s:12:"TDS accuracy";s:11:"± 1 % F.S.";s:10:"TDS factor";s:23:"0.1 - 1.0 (default 0.5)";}
a:3:{s:9:"TDS range";s:55:"0-100 ppt. (max. 200 ppt., depending on factor setting)";s:12:"TDS accuracy";s:11:"± 1 % F.S.";s:10:"TDS factor";s:23:"0.1 - 1.0 (default 0.5)";}
a:3:{s:9:"TDS range";s:0:"";s:12:"TDS accuracy";s:0:"";s:10:"TDS factor";s:0:"";}
Salinity measurement
▾
a:3:{s:14:"Salinity range";s:28:"0 to 100 ppt. (max. 80 ppt.)";s:17:"Salinity accuracy";s:10:"± 1 % F.S";s:17:"Measurement modes";s:30:"Seawater or practical salinity";}
a:3:{s:14:"Salinity range";s:0:"";s:17:"Salinity accuracy";s:0:"";s:17:"Measurement modes";s:0:"";}
Resistivity
▾
a:3:{s:17:"Resistivity range";s:11:"0 to 100 Ω";s:20:"Resistivity accuracy";s:10:"± 1 % F.S";s:22:"Resistivity resolution";s:12:"0.01, 0.1, 1";}
a:3:{s:17:"Resistivity range";s:0:"";s:20:"Resistivity accuracy";s:0:"";s:22:"Resistivity resolution";s:0:"";}
Dissolved oxygen
▾
a:7:{s:22:"DO concentration range";s:18:"0.00 to 20.00 mg/L";s:11:"DO accuracy";s:11:"± 0.2 mg/L";s:18:"Calibration points";s:12:"1 - 2 points";s:19:"Pressure correction";s:33:"60.0 to 112.5 kPa, 450 - 850 mmHg";s:19:"Salinity correction";s:11:"0 to 50 g/L";s:22:"% Saturation of Oxygen";s:14:"0.0 to 200.0 %";s:8:"Accuracy";s:8:"± 2.0 %";}
a:7:{s:22:"DO concentration range";s:0:"";s:11:"DO accuracy";s:0:"";s:18:"Calibration points";s:0:"";s:19:"Pressure correction";s:0:"";s:19:"Salinity correction";s:0:"";s:22:"% Saturation of Oxygen";s:0:"";s:8:"Accuracy";s:0:"";}
Dimension(L × W × H)
▾
185 × 88 × 32 mm
pH range
▾
(-2.00) to 16.00 pH
(-2.00) to 20.00 pH
Temperature measuring range
▾
0 to 100 °C, 32 to 212 °F
Storage/memory
▾
Stores up to 50 data sets
Stores up to 500 data sets
Communication output
▾
USB
USB interface
Price Range
Select Price Range
Up to $500
$501 - $1000
$1001 - $5000
$5001 - $10000
$10001 and above
Water Testing Instruments
Benchtop Conductivity Meter
Benchtop Dissolved oxygen meter
Benchtop Ion Meter
Benchtop Water hardness meter
Conductivity Tester
Dissolved Oxygen tester
Multi-parameter water quality Analyzer
ORP tester
pH Meter (Benchtop)
pH Tester (POCKET)
Portable dissolved oxygen meter
Portable Multi Parameter Water Quality Meter
pH Meter (Portable)
Portable water hardness meter
Salinity Tester
TDS tester
Turbidity Meter