info@labsearch.com
List Your Company
+ Add Product
Get Quote
Track Order
0
Sign In
Supplier / Distributor
Home
All Category
Catalogs
Sign In
Login
Add to Cart
Home
All Category
About Us
Contact Us
Get Quote
Name
Email
Product Name
Submit
Home
›
Thermal Cycler
Filters
Capacity
▾
96 × 0.2 ml
96 × 0.2 ml + 77 × 0.5 ml
54 × 0.5 ml
384 well
60 × 0.5 ml
Double (each block with) 48×0.2ml
48×0.2ml and 30×0.5ml
Block Temperature Range
▾
0 to 99.9°C
0 to 100℃
Temperature Control Accuracy
▾
≤ ± 0.2 ℃
≤ ± 0.1 ℃
Ramping Rate Adjustable
▾
0.1 to 2.5℃
0.1 to 5℃
Temperature Uniformity
▾
≤ ± 0.3 ℃
≤ ± 0.2 ℃
≤±0.25℃
Heating Rate
▾
4 ℃/s
5 ℃/s
Cooling Rate
▾
3 ℃/s
4 ℃/s
Temperature Control Mode
▾
Block \ Tube
Hot-lid Temperature Range
▾
30 to 110℃
Hot Lid Height Adjustable
▾
Stepless Adjustable
Max No. of Steps
▾
9
30
Max No. of Cycles
▾
99
Time Increment/Decrement
▾
1 sec to 9 min 59 sec
3 sec to 9 min 59 sec
Temperature Increment/Decrement
▾
0.1 to 9.9℃
Program
▾
200
Max 20 Segments for Each Program, Max 99 Cycles
10000+(USB FLASH)
Pause Function
▾
Yes
Auto Data Protection
▾
Yes
Print
▾
Yes
LCD
▾
5.7 inch, 320 × 240 pixels
8 inch,800×600 Pixels, 16 colors TFT touch screen
Communication
▾
USB 2.0 , RS232
USB 2.0 , LAN
Power Supply
▾
85 to 264 V AC , 47 to 63 Hz , 600 W
100 to 240 V, 50/60 Hz, 600 W
100 to 240 V, 50/60 Hz, 650 W
220VAC,50HZ
Dimension ( L×W×H )
▾
380 × 240 × 260 mm
392 × 262 × 252 mm
Weight
▾
10 kg
25 kg (Without computer)
8.5 kg
3kg
Gradient Temperature Range
▾
30 to 99.9℃
30 to 100℃
Gradient Unformity
▾
≤ ± 0.3℃
≤ ± 0.2 ℃
Gradient Accuracy
▾
≤ ± 0.2℃
≤ ± 0.2 ℃
Gradient Spread
▾
1 to 30℃
Sample Capacity
▾
12 × 8 (96 wells with 0.2 ml each) plate, 96 × 0.2 ml tubes (Bottom Transparent)
96-Well PCR plate12 × 8-strip <br/> 96 × 0.2 ml(Bottom Transparent)
48 × 0.2 ml
8×0.2ml(8 well)
Emission Wavelength
▾
500 to 800 nm
Standard channels: F1 : 525 nm F2 : 564 nm F3 : 584 nm F4 : 612 nm
F1 : 525 nm F2 : 564 nm
500 to 800nm
Excitation Wavelength
▾
300 to 800 nm
Standard channels: F1 : 470 nm F2 : 523 nm F3 : 543 nm F4 : 571 nm
F1 : 470 nm F2 : 523 nm
300 to 800nm
Sample Volume Range
▾
5 to 100μl
10 to 100μL
Dynamics Range
▾
10 to 10<sup>10</sup> Copies
Max. channels number of fluorescence detection
▾
5 channels
2 channels
4 channels
6 channels
8 channels
Detected Fluorescence
▾
F1 : FAM, SYBR Green 1; F2 : VIC HEX TET JOE CY3 TAMRA; F3 : ROX TEXAS-RED; F4 : CY5 Quasar-670; F5 : CY5.5 Quasar-705
F1 : FAM, SYBR Green 1; F2 : VIC HEX TET JOE
F1 : FAM, SYBR Green 1; F2 : VIC, HEX, TET, JOE; F3 : CY3, NED, TAMRA; F4 : ROX,TEXAS-RED
F1 : FAM SYBR Green I; F2 : VIC HEX TET JOE; F3 : CY3 NED TAMRA; F4 : ROX TEXAS-RED; F5 : Cy5; F6 : ht cycler red
F1 : FAM, SYBR Green I F2 : VIC, HEX, TET, JOE F3 : CY3,NED,TAMRA F4 : ROX, TEXAS-RED F5 : Cy5 F6 : Light cycler red F7,F8 for Customized
F1:FAM,SYBR Green I; F2: HEX,VIC F3:TAMRA,JOE,Cy3 F4:TEX RED,ROX
F1:FAM,SYBR Green I; F2: HEX VIC
Block Temp. Range
▾
4 to 105℃ (Minimum Increment: 0.1℃), SOAK Low Temp. Conservation Function
4 to 99.9℃
Temp. Control Accuracy
▾
≤ ± 0.1 ℃
≥ 4.0 ℃/sec
Temp. Fluctuation
▾
≤ ± 0.1 ℃
Temp. Uniformity
▾
≤ ± 0.3 ℃
Ramping Rate
▾
4.0 ℃/sec
Temp. Control Mode
▾
BLOCK/Tube Simulation Mode (Automatic Control based On Sample Volume )
Gradient Temp. Range
▾
1 to 36 ℃
1 to 36℃
1 to 24 ℃
Hot-lid Temp. Range
▾
30 to 110℃ (Adjustable, default 105℃, Automatic Hot-lid )
80℃ to 110℃
Fluorescence Detection Repeatability
▾
0.05
Operation Mode
▾
Continuous
Scan Mode
▾
Entire Plate or Designated Line
Scan Period
▾
5.5 sec
Feature Function
▾
Absolute Quantification; Relative Quantification; SNP Analysis; Data Automatic Analysis; Melting Curve Genotyping; Gradient; HRM Multi-channel Crosstalk Correction; Background Correction; Automatic Gain; Customized Parameters
Quantitative/qualitative, melting curve, genotyping
Operation System
▾
Microsoft: Windows XP/Windows vista/Windows 7/Windows 8 Software: Excel2000/2002/2003/2007/2012
Microsoft: Windows2000/XP/vista/Windows7 Software: Excel2003/2007 Access: 2003/2007
Windows 2000/XP
PC Configuration
▾
Memory : 512 M; Hard Disk : 10 GB; CPU : Pentium® 4; Virtual Memory : ≥ 1000 MB
Dimension ( L × W × H )
▾
410 × 386 × 352 mm
430 x 395 x 352 mm
520 x 450 x 320 mm
Socket
▾
USB Adapter; Bluetooth Adapter
RS 232C Adapter
Tablet
▾
Microsoft Surface 2 pro
Consumable
▾
Clear 0.2 ml PCR tube /8-tube strips
Reaction Volume
▾
15 to 100μl
Temperature Control Technology
▾
Marlow customized Peltier allow 1.000.000 cycles
Temperature Range
▾
0 to 100℃
Temperature Resolution
▾
0.1℃
Temperature Fluctuation
▾
≤±0.1℃
Temperature Accuracy
▾
≤±0.25℃
Hot Lid Temperature
▾
30 to 110℃ (Adjustable, default 105℃)
Temperature Control
▾
Block/Tube
Factory Calibrated Dyes
▾
F1: FAM/SYBR Green I<br>F2: HEX/VIC/JOE/TET<br>F3: ROX<br>F4: CY5
Max. Ramp Rate
▾
7℃/s
Detection
▾
High-sensitivity photoelectric detector
Dynamic Range
▾
1 to 10¹⁰ copies
Sensitivity
▾
1 copy
Date Export Formats
▾
Excel CVS, txt
Communication Interface
▾
WIFI/USB2.0
Power Consumption
▾
DC15V 225W
Dimension (L×W×H)
▾
195×165×140 mm
Price Range
Select Price Range
Up to $500
$501 - $1000
$1001 - $5000
$5001 - $10000
$10001 and above
Thermal Cycler
Advanced Thermal Cycler
Touch Thermal Cycler
Real Time PCR
Enquiry Form
Enquiry Form
Name
Email
Product Name
Submit