Sample (size) length
▾
Diameter ≥30 mm, Thickness ≤ 40 mm
38×70 mm
90 to 200 mm
180 mm (180, 150, 100, 90, 50 mm adjustable)
0 to 200 mm adjustable
Measurement mode
▾
Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability
▾
≤ 0.1 within 30 min
Accuracy
▾
Chromaticity co-ordinate 0.0001
± 1 %
0.01 or 0.001 mm
0.01 mm
± 1%
± 0.5 % F.S.
±0.1 s within 300 s
Repeatability
▾
Rx, Ry and Rz s ≤ 0.1 chromaticity co-ordinate s ≤ 0.0010, R457 s ≤ 0.10
System
▾
D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150 mm, testing hole diameter 30 mm
D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light measurement
▾
CIE whiteness (Ganz whiteness W10, Color cast value TW10), WH hunter whiteness, YI Yellowness, ISO brightness R457
Storage
▾
9 reference samples
Dimension (L*W*H)
▾
360 × 264 × 400 mm
220 × 230 × 350 mm
920 × 420 × 300 mm
800 × 270 × 200 mm
450 × 550 × 120 mm
Net weight
▾
23 kg
20 kg
15 kg
65 kg
40 kg
55 kg
75 kg
30 kg
35 kg
Power supply
▾
220 V ± 10 %, 50 Hz
AC220 V ± 10 % , 50 Hz
Light source
▾
D65 as illuminating source
Zero drift
▾
≤ 0.1 %
Indication drift
▾
≤ 0.1 %
Indication error
▾
≤ 0.5 %
0.02
< ± 1%
± 1 %
Repeatability error
▾
≤ 0.1 %
Mirror reflection error
▾
≤ 0.1 %
Measuring range
▾
(1-500) mN.m (divided into 7 small ranges)
0 to 30, 0 to 100 N,0 to 300 N
0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
0 to 4 mm
0 to 20 mm
10 to 1000 mN
0.1 to 10 kN
1 to 50 kN
0 to 1000 ml/min
A (1 to 6) J indicating error ± 0.05 J<br/> B (1 to 12) J indicating error ± 0.05 J<br/> C (1 to 24) J indicating error ± 0.05 J<br/> D (1 to 48) J indicating error ± 0.05 J<br/> The indicating errors w.r.t measurement range of 20 to 80 %
0 to 1000 mN
Test speed
▾
(200° ± 20°)/ min
Sample width
▾
15 mm, 25 mm, 50mm
15 mm
Tensile strength velocity
▾
1 to 399 mm/min (adjustable)
Tensile return velocity
▾
1 to 399 mm/min (adjustable)
Sample loading
▾
Full automatic to clamp the sample
Semi-automatic , can clamp the sample using hands
Clamp air pressure
▾
0.4 to 0.6 MPa
Measurement range
▾
0 to 100° SR
0 to 200 mm
0.01 to 10 N
0 to 5600 kPa
0 to 1600 kPa
5 to 500 N, 50 to 3000 N
Sealed testing speed
▾
100 ± 10 mm/s
Volume of distilled water
▾
1000 ± 5 ml
Draining time
▾
149 ± 1 s
Residual water volume
▾
7.85 to 8 ml
Hydraulic pressure
▾
>0.3 MPa
Dimension
▾
450×250×1100 mm
420×250×380 mm
270×400×300 mm
240×288×435 mm
200×230×350 mm
233×160×120 mm
275×302×297 mm
240×520×70 mm
570×410×200 mm
410×300×1160 mm
700×340×600 mm
800×470×840 mm
480×420×600 mm
450×400×500 mm
325×390×430 mm
320×320×450 mm
Net Weight
▾
40 kg
15 kg
35 kg
25 kg
Specimen size
▾
15×250 mm
Division value
▾
1 mm
1 mN
Number of specimen holders
▾
5
Metal Cylinder inner area
▾
(100 ± 0.2) cm2
Metal Cylinder height
▾
50 mm
Metal roller width
▾
(200 ± 0..5) mm
Metal roller weight
▾
(10 ± 0.5) kg
Absorbency paper
▾
200 to 250 g/m2
Absorbency speed
▾
75 mm/10 min
Sample diameter
▾
125 mm
Sample error
▾
± 0.2 mm
Sample Thickness
▾
0.1 to 1.0 mm
Slider weight
▾
200 g
Slider size
▾
63×63 mm
Testing accuracy
▾
± 2 %
Dimension of working plate
▾
170×225 mm
Speed of slider
▾
100 ± 1 0mm/min
Slider stroke
▾
Max 100 mm (adjustable)
Testing speed
▾
200° ± 20° / min
Test range
▾
1 to 10000 mN
Indicating Error
▾
± 1 %
± 0.0025 mm or ± 0.5 %
≤ 0.5
Testing length
▾
5, 10, 15, 20, 25, 50 mm
Sample size
▾
Width 38 ± 0.2 mm, length 70 mm
Bend angle
▾
1 to 90°
Weight
▾
15 kg
5.5 kg
25 kg
4 kg
33 kg
About 15kg
92 g
185 kg
20 kg
Gauge
▾
Analogue gauge display
Contact pressure (to create false weight)
▾
100 ± 10 kPa
20 ± 0.5 kPa
Contact diameter
▾
16.0 ± 0.5 mm
35.7 ± 0.5 mm
Error of depth parallelism
▾
0.005 mm or 1 %
0.03 mm
Indication variability
▾
≤ 0.0025 mm or ≤ 0.5 %
Sample size (L*B)
▾
230×50 mm (can join short samples together)
Rub pressure
▾
20 ± 0.2 N
Friction speed
▾
43 times / min
Friction area (L*B)
▾
155×50 mm
No. of friction
▾
0 to 999, auto shutdown
Sample maximum length
▾
300 mm
Parallelism
▾
≤ 0.1 mm
Pressing depth of the measuring head
▾
8 + 0.5 mm
Parallelism error between two brims of the specimen stages
▾
≤ 0.05 mm
Slit width of the specimen stage
▾
5 mm, 6.35 mm, 10 mm, 20 mm
Platen Size
▾
500×500 mm (customized)
800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized)
Operating stroke
▾
500 mm (customized)
800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized)
Compression speed
▾
10 mm/ min
170 ± 15 ml/min
95 ± 5 ml/min
Speed adjustment range
▾
2 to 100 mm/ min
Track & force speed in stacking test
▾
2 mm/ min
Test area
▾
10 ± 0.02 cm2
Area differential pressure
▾
1 ± 0.01 kPa
Inner diameter of grip ring
▾
35.68 ± 0.05 mm
Capacity
▾
A: 20 to 500 J/m2 B: 500 to 1000 J/m2
10 -16000 mN
Impact angle
▾
90°
Unit
▾
Lb-ft/in2 J/m2
Error
▾
A: ± 1 J/m2 B: ± 2 J/m2
Sample amount
▾
5 pcs
Frictional resistance
▾
<0.25 J
Pyramid dimension
▾
Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm
Resolution
▾
0.1 mN
1 N
Tearing arm
▾
104 ± 1 mm
Tearing angle
▾
27.5° ± 0.5°
27.5° ± 5°
Tearing distance
▾
43 ± 0.5 mm
Chips distance
▾
180 mm
Clamp- paper
▾
2.8 ± 0.3 mm
Resection length
▾
20 ± 0.5 mm
Clamp pressure
▾
≥ 690 kPa
≥ 430 kPa
Diameter of upper clamp
▾
31.5 ± 0.05 mm
30.5 ± 0.05 mm
Diameter of lower clamp
▾
31.5 ± 0.05 mm
33.1 ± 0.05 mm
Pneumatic pressure
▾
0.45 to 0.6 MPa
0.3 to 0.5 MPa
Film resistance
▾
For bulge height = 10 mm, The pressure = 170 to 220 kPa<br/> For bulge height = 18 mm, The pressure = 250 to 350 kPa
For bulge height = 9 mm, The pressure = 25 to 35 kPa
Variability
▾
≤ 1 %
Speed
▾
12.5 ± 2.5 mm/min
Maximum distance
▾
78 mm
Measuring scope
▾
( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
0 to 99999 s
Vacuum system volume (ml)
▾
Bigger volume: 380 ± 1<br/> Smaller volume: 38 ± 1
Contact pressure
▾
100 ± 2 kPa
Vacuum scope
▾
I) 50.66 to 48.00<br/> II) 50.66 to 48.00<br/> III) 50.66 to 29.33<br/> Automatic: No limit
Air volume (50.66 kPa down to 48.00 kPa)
▾
Big vacuum volume: 10.00 ± 0.20 ml<br/> Small vacuum volume: 1.00 ± 0.05 ml
Folding angle
▾
135° ± 2°
Tensile scope
▾
4.9 to 14.7 N
Folding head suture size
▾
0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm
Folding radius
▾
0.38 ± 0.02 mm
Price Range
Select Price Range
Up to $500
$501 - $1000
$1001 - $5000
$5001 - $10000
$10001 and above