HPLC System 37-HPS201

HPLC System 37-HPS201

This HPLC system delivers high quality performance and reliable results in order to meet the stringent requirements of the customer. To meet GMP/GLP requirements of the instrument, this HPLC system has hardware with VP function which records maintenance information and operations.

$8110
High pressure pump High pressure constant-current infusion pump
Infusion Way Micro volume series dual-piston
Infusion pressure 0 - 9999 Psi
Flow rate ≤ 0.5 %
Flow rate range 0.001 - 9.999 mL / min (in 0.001 mL / min increments)
Stability error for the flow rate ≤ 0.2 % RSD
Gradient error ± 1 % (0 - 100 % water/acetone solvent)
Pressure pulsation < 15 Psi (flow rate 1 mL / min, pressure 600 - 1600 Psi)
Air tightness Pressure 5400 Psi, 10 min time, pressure drop < 400 Psi
Time program function Yes
Size (W × H × D) 260 × 130 × 420 mm
Weight 11 kg
Operation temperature 4 - 40 ºC
UV detector a:18:{s:16:"Wavelength range";s:3:"240";s:16:"Wavelength error";s:8:"≤ 1 nm";s:30:"Wavelength repeatability error";s:13:"≤ ± 0.1 nm";s:13:"Dynamic noise";s:77:"≤ ± 0.75 × 10-5 AU (methyl alcohol 1 mL / min, 254 nm, 20 ºC)";s:12:"Static noise";s:77:"≤ ± 0.5 × 10-5 A (empty cell, response time, 1 second, 20 ºC)";s:22:"Dynamic baseline Drift";s:78:"≤ ± 1 × 10-4 AU / h (methyl alcohol 1 mL / min, 254 nm, 20 ºC)";s:21:"Static baseline Drift";s:73:"≤ 0.5 × 10-4 (empty cell, response time, 1 second, 20 ºC)";s:12:"Linear range";s:7:"≥ 104";s:18:"Limit of detection";s:69:"≤ 1 × 10-9 g / ml (Naphthalene methyl alcohol solvent)";s:26:"Quantitative repeatability";s:15:"RSD 6 ≤ 0.1 %";s:25:"Qualitative repeatability";s:15:"RSD 6 ≤ 0.5 %";s:19:"Spectrum band width";s:4:"6 nm";s:16:"Flow cell volume";s:5:"8 µL";s:12:"Optical path";s:5:"10 nm";s:21:"Time program function";s:3:"Yes";s:18:"Size (W × H × D)";s:20:"260 × 130 × 420 mm";s:6:"Weight";s:5:"11 kg";s:21:"Operation Temperature";s:10:"4 - 40 ºC";}
  • High pressure constant-current infusion pump
    Even mixing of the injections using mixers
    Supreme appearance to meet the customer’s visual requirements
    Simple, easy to use operations
    UV detector unit consists of dual beam monochromator, light battery, deuterium lamp
  • This HPLC has applications in the scientific research studies, detection of residual amount in medicine, food, alcohol and in chemical analysis.

Analytical HPLC

Analytical HPLC 37-AHP100

  • Pump Specifications :
    Model No HPP-A1
    Flow rate range 0.0001 ~ 10 ml / min
    Maximum pressure 50 MPa , 0 ~ 2 ml / min
    Column size 4.6 x 250 mm11
    Sample size 5 µm
    Pressure pulsation ≤ 1 % at 10 MPa
    Flow rate accuracy ± 0.15 % at 1 ml / min
    Flow rate repeatability % ≤ 0.1
    Gradient accuracy % ± 1.5
    Gradient repeatability % ≤ 0.2
    Dimension 460 x 310 x 180 mm
    Power supply 90 V
    Weight 11.6 kg
  • Detector Specifications :
    Model No HPD-A20 HPD-A21
    Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm )
    Wavelength accuracy ± 0.5 nm ± 2 nm
    Wavelength repeatability 0.15 nm 0.3 nm
    Band width 8 nm 8 nm
    Optical path 10 nm 10 nm
    Deuterium lamp 190 ~ 400 nm 190 ~ 400 nm
    Tungsten lamp 400 ~ 800 nm 400 ~ 800 nm
    Baseline noise ( Static ) Au ≤ ± 0.35 x 10 -5 ≤ ± 0.5 x 10 -5
    Baseline drift ( Static ) Au / h ≤ 1 x 10 -4 ≤ 1.5 x 10 -4
    Minimum detection limit ≤ 4 x 10 -8 ≤ 4 x 10 -8
    Power 100 W 100 W
    Power supply 90 V / 50 ~ 60 Hz 90 V / 50 ~ 60 Hz
    Dimension 460 x 315 x 180 mm 460 x 315 x 180 mm
    Weight 9.5 kg 9.5 kg
$12160

Analytical HPLC 37-AHP101

  • Pump Specifications :
    Model No HPP-B1
    Flow rate range 0.0001 ~ 10 ml / min
    Maximum pressure 42 MPa , 0 ~ 5 ml / min
    Column size 4.6 x 250 mm11
    Sample size 5 µm
    Pressure pulsation ≤ 1.5 % at 10 MPa
    Flow rate accuracy ± 0.2 % at 1 ml / min
    Flow rate repeatability % ≤ 0.15
    Gradient accuracy % ± 2
    Gradient repeatability % ≤ 0.2
    Dimension 450 x 260 x 190 mm
    Power supply 90 V ~ 240 V
    Weight 11.2 kg
  • Detector Specifications :
    Model No HPD-B2
    Wavelength range 190 to 800 nm
    Wavelength accuracy ± 0.75 nm
    Wavelength repeatability 0.2nm
    Band width 8 nm
    Optical path 10 nm
    Deuterium lamp 190 ~ 400 nm
    Tungsten lamp 400 ~ 800 nm
    Baseline noise ( Static ) Au ≤ ± 0.5 x 10 -5
    Baseline drift ( Static ) Au / h ≤ 1.5 x 10 -4
    Minimum detection limit ≤ 4 x 10 -8
    Power 100 W
    Power supply 90 V / 50 ~ 60 Hz
    Dimension 460 x 260 x 190 mm
    Weight 9.2 kg
$13600

Preparative HPLC

Preparative HPLC 37-PHP100

  • Dimension : 750 x 860 x 1280 mm ( 100 ml , 250 ml , 500 ml , 1000 ml ) , 810 x 950 x 1310 mm ( 3 L )
  • Wetted material : 316 L and PTFE
$27425

Semi-prep HPLC

Semi-prep HPLC 37-SPH100

  • Pump Specifications :
    Model No SPH-A10 SPH-A11 SPH-A12 SPH-A13
    Flow rate range 0.001 ~ 50 ml / min 0.001 ~ 50 ml / min 0.001 ~ 100 ml / min 0.001 ~ 100 ml / min
    Maximum pressure 30 MPa 30 MPa 15 MPa 10 MPa
    Flow rate accuracy ± 0.35 ± 0.5 ± 0.5 ± 0.5
    Flow rate repeatability % ≤ 0.1 ≤ 0.15 ≤ 0.1 ≤ 0.15
    Column size 10 x 250 mm 10 x 250 mm 10 x 250 mm 10 x 250 mm
    Sample loading 35 ~ 60 mg 35 ~ 60 mg 35 ~ 60 mg 35 ~ 60 mg
    Pressure pulsation 1 % at 10 MPa 1.5 % at 10 MPa 1.5 % at 10 MPa 1.5 % at 10 MPa
    Flow rate repeatability % ≤ 0.1 ≤ 0.15
    Gradient accuracy % ± 2 ± 2 ± 2 ± 2
    Gradient repeatability % ≤ 0.2 ≤ 0.2 ≤ 0.2 ≤ 0.2
    Dimension 465 x 315 x 180 mm 455 x 265 x 190 mm 465 x 315 x 180 mm 465 x 315 x 180 mm
    Power 150 W 150 W 150 W 150 W
    Power supply 90 V ~ 240 V/ 50 Hz 90 V ~ 240 V/ 60 Hz 90 V ~ 240 V/ 50 Hz 90 V ~ 240 V/ 60 Hz
    Weight 11.6 kg 11.2 kg 11.6 kg 11.6 kg
  • Detector Specifications :
    Model No SPH-A20 SPH-A21 SPH-A22
    Wavelength range 190 to 800 nm 190 to 800 nm 190 to 800 nm
    Wavelength accuracy ± 0.5 nm ± 1 nm ± 0.75 nm
    Wavelength repeatability 0.15 nm 0.3 nm 0.2 nm
    Band width 8 nm 8 nm 8 nm
    Optical path Semi flow / analytical Semi flow / analytical Semi flow / analytical
    Baseline noise ( Static ) Au ≤ ± 0.35 x 10 -5 ≤ ± 0.5 x 10 -5 ≤ ± 0.5 x 10 -5
    Baseline drift ( Static ) Au / h ≤ 1 x 10 -4 ≤ 1.5 x 10 -4 ≤ 1.5 x 10 -4
    Minimum detection limit ≤ 4 x 10 -8 ≤ 4 x 10 -8 ≤ 4 x 10 -8
    Power 150 W 150 W 150 W
    Power supply 90 V / 50 ~ 60 Hz 90 V / 50 ~ 60 Hz 90 V / 50 ~ 60 Hz
    Dimension 465 x 315 x 180 mm 465 x 315 x 180 mm 460 x 265 x 190 mm
    Weight 9.5 kg 9.5 kg 9.2 kg
$12640
Enquiry Form
Captcha Image