Ion chromatograph system 30-ICG200

Ion chromatograph system 30-ICG200

Ion chromatograph system 30-ICG200 is a modular design ion chromatograph with an upgraded circuit technology. With gradient elution system detects small molecules from complex samples. Bipolar conductivity detector, improves the detection performance and stability of the instrument.

$37540
Ion Chromatographic Pump a:6:{s:4:"Type";s:64:"High pressure and low pulse double plunger tandem advection pump";s:16:"Maximum pressure";s:13:"35 MPa (PEEK)";s:25:"Pressure display accuracy";s:11:"≤ 0.1 MPa";s:14:"Flow stability";s:91:"(0.2 to 0.5) ml/ min ≤ 3 %
(0.5 to 1.0) ml/ min ≤ 2 %
> 1.0 ml/ min 2 %
";s:10:"Flow range";s:22:"0.001 to 9.999 ml/ min";s:14:"Pressure pulse";s:8:"≤ 0.5%";}
Conductivity detector a:16:{s:4:"Type";s:53:"Temperature Control and Bipolar Conductivity Detector";s:14:"Detection mode";s:30:"Bipolar conductivity detection";s:11:"Cell volume";s:11:"≤ 0.8 µL";s:15:"Detection range";s:18:"0 to 35000 µS/ cm";s:20:"Detection resolution";s:17:"≤ 0.0020 nS/ cm";s:14:"Output voltage";s:31:"- 6000 to +6000 mV (adjustable)";s:14:"Baseline noise";s:15:"≤ 0.05 % F.S.";s:14:"Baseline drift";s:18:"≤ 3 % FS/ 30 min";s:27:"Operating temperature range";s:43:"Room temperature +5 to 60°C (41 to 140°F)";s:32:"Controlling temperature accuracy";s:10:"± 0.01°C";s:16:"Maximum pressure";s:6:"10 MPa";s:12:"Linear range";s:7:"≥ 103";s:21:"Instruments linearity";s:9:"≥ 0.999";s:26:"Quantitative repeatability";s:9:"≤ 1.0 %";s:25:"Qualitative repeatability";s:9:"≤ 1.0 %";s:32:"Minimum detectable concentration";s:73:"Cl ≤ 0.0005 ug/ ml
BrO3 ≤ 0.001 ug/ ml
Li+ ≤ 0.001 ug/ ml";}
Flow system a:2:{s:17:"Plastic flow path";s:22:"Made of PEEK materials";s:13:"Six way Valve";s:84:"PEEK material, 5000 psi pressure, independent automatic collection and flow function";}
Degassing Device a:5:{s:12:"Inner volume";s:7:"300 µl";s:16:"Degassing volume";s:6:"7.5 ml";s:17:"Maximum flow rate";s:10:"10 ml/ min";s:20:"Degassing efficiency";s:26:"Degassing 90 % at 1ml/ min";s:17:"Organic tolerance";s:1:"1";}
Built-in Eluent Generator a:6:{s:12:"Eluent types";s:9:"KOH/ NaOH";s:26:"Eluent concentration range";s:13:"0.1 to 100 mM";s:23:"Concentration increment";s:6:"0.1 mM";s:16:"Flow rate change";s:18:"0.1 to 3.0 ml/ min";s:16:"Maximum pressure";s:6:"20 MPa";s:16:"Minimum pressure";s:5:"5 MPa";}
Power supply 150 W
External dimension 350 × 470 × 650 mm
Net weight 34 kg
Gross weight 40 kg
  • Built-in eluent generator
    Maintains excellent system thermal stability
    Built-in low pressure degassing technology
    Automatic, self-regenerating electrolytic microfilm suppressor
    Automatic standard dilution function, saves manpower time and cost
    Built-in circulating stereo constant temperature
    Complete solution support with 3 & 5 warranty policy
    RS232, USB Interface
    User-friendly operations
  • Used to detect small molecules (in the form of anion, cation) in food, chemical, mining, metallurgy, environment and other fields.

Customer Reviews

Gas Chromatography

Gas Chromatography 30-GCG100

  • Chromatography column type : Capillary and Packed column
  • Chromatography column length : 100 to 500 mm
$4070

Gas Chromatography 30-GCG101

  • Chromatography column type : Capillary or Packed column
  • Chromatography column length : 100 to 300 mm
$14260

Gas Chromatograph 65-GC104

  • Temperature Range : RT to 450 °C
  • Temperature Accuracy : ≤ ± 0.1℃
$5610

Gas Chromatograph Mass Spectrometer

Gas-Chromatograph-Mass Spectrometer 30-GMS100

  • Gas Chromatography Specifications : a:12:{s:8:"Model No";s:5:"GC-87";s:9:"Flow rate";s:16:"1 ~ 1.5 ml / min";s:17:"Maximum flow rate";s:11:"10 ml / min";s:17:"Inlet temperature";s:7:"450 °C";s:14:"Pressure range";s:11:"0 ~ 100 psi";s:12:"Heating rate";s:18:"Upto 120 °C / min";s:16:"Room temperature";s:17:"4 °C ~ 450 °C";s:21:"Pressure control mode";s:50:"Electronic pressure control ( Supports CV and CC )";s:10:"Split mode";s:18:"Split / split less";s:11:"Split ratio";s:8:"1000 : 1";s:23:"Temperature programming";s:22:"7 stages / 8 platforms";s:12:"Auto sampler";s:8:"Optional";}
  • Mass Spectrometry Specifications : a:12:{s:8:"Model No";s:5:"MS-89";s:10:"Mass range";s:14:"1.5 ~ 1000 amu";s:26:"Ion – source temperature";s:19:"100 °C ~ 350 °C";s:27:"GC-MS interface temperature";s:7:"450 °C";s:9:"Scan rate";s:16:"Upto 10000 amu/s";s:9:"Stability";s:21:"± 0.10 amu / 48 hrs.";s:25:"Filament emission current";s:11:"0 ~ 350 µA";s:27:"EI source ionization energy";s:13:"5 eV ~ 250 eV";s:10:"Resolution";s:15:"Unit resolution";s:8:"Detector";s:38:"High energy dynode electron multiplier";s:11:"Sensitivity";s:33:"Full scan ( S / N is ≥ 30 : 1 )";s:6:"Vacuum";s:31:"Turbo molecular pump ( 67 L/s )";}
$46000

Enquiry Form

Captcha Image