Gas Chromatography Specifications
▾
a:12:{s:8:"Model No";s:5:"GC-87";s:9:"Flow rate";s:16:"1 ~ 1.5 ml / min";s:17:"Maximum flow rate";s:11:"10 ml / min";s:17:"Inlet temperature";s:7:"450 °C";s:14:"Pressure range";s:11:"0 ~ 100 psi";s:12:"Heating rate";s:18:"Upto 120 °C / min";s:16:"Room temperature";s:17:"4 °C ~ 450 °C";s:21:"Pressure control mode";s:50:"Electronic pressure control ( Supports CV and CC )";s:10:"Split mode";s:18:"Split / split less";s:11:"Split ratio";s:8:"1000 : 1";s:23:"Temperature programming";s:22:"7 stages / 8 platforms";s:12:"Auto sampler";s:8:"Optional";}
Mass Spectrometry Specifications
▾
a:12:{s:8:"Model No";s:5:"MS-89";s:10:"Mass range";s:14:"1.5 ~ 1000 amu";s:26:"Ion – source temperature";s:19:"100 °C ~ 350 °C";s:27:"GC-MS interface temperature";s:7:"450 °C";s:9:"Scan rate";s:16:"Upto 10000 amu/s";s:9:"Stability";s:21:"± 0.10 amu / 48 hrs.";s:25:"Filament emission current";s:11:"0 ~ 350 µA";s:27:"EI source ionization energy";s:13:"5 eV ~ 250 eV";s:10:"Resolution";s:15:"Unit resolution";s:8:"Detector";s:38:"High energy dynode electron multiplier";s:11:"Sensitivity";s:33:"Full scan ( S / N is ≥ 30 : 1 )";s:6:"Vacuum";s:31:"Turbo molecular pump ( 67 L/s )";}
Chromatography column type
▾
Capillary and Packed column
Capillary or Packed column
Chromatography column length
▾
100 to 500 mm
100 to 300 mm
Chromatography column diameter
▾
0.2 to 0.5 mm
Temperature operating range
▾
Higher than the room temperature of 5 ℃ to 450 ℃
Higher than the room temperature of 5 °C to 450°C<br/> Liquid nitrogen cold trap: -80 °C to 400 °C<br/> Dry ice cold trap: -55 °C to 400 °C
Maximum programmed heating speed
▾
120 ℃/min
120 °C/min
Programmed temperature steps
▾
7 steps
Temperature setting precision
▾
1 °C
0.1 °C
Programmed heating rate
▾
0.1 to 120 °C/min (increment of 0.1 °C)
0.1 to 120 º C/min (increment of 0.1°C)
Furnace dimension
▾
280 × 300 ×180 mm
Injectors
▾
Packed column injectors, split/split less capillary column injectors, cool on-column injectors
Detectors
▾
Following detectors can be selected as per the requirement
FID
▾
Maximum temperature control: 400 °C <br/> LOD: ≤ 5 × 10<sup>12</sup> g / s [n - C16] <br/> Linear dynamic range: ≥ 10<sup>7</sup> <br/> Drift: ≤ 5 × 10<sup>-13</sup> A / 30 min <br/> Noise: ≤ 2 × 10<sup>-13</sup> A
Maximum using temperature: 450 °C<br/> Minimum LOD: ≤ 2.5 pg C / s [n - C16]<br/> Linear dynamic range: 10<sup>7</sup> (± 10 %)<br/> Data collection frequency: Maximum 100 Hz
TCD
▾
Maximum temperature control: 400 °C<br/> LOD: ≥ 10000 mv.ml / mg [n - C16]<br/> Linear dynamic range: ≥ 10<sup>4</sup> <br/> Drift: ≤ 10 µV / 30 min<br/> Noise: ≤ 20 µA
Maximum using temperature: 400 °C<br/> Minimum LOD: < 400 pg C3 H8 / ml(He)<br> Linear dynamic range: 10<sup>5</sup> (± 5 %)<br/> Data collection frequency: Maximum 100 Hz<br/> The design of monofilament TCD and Micro-ECD
FPD
▾
Maximum temperature control: 250 °C<br/> LOD: ≤2×10<sup>-13</sup> g / s (P), ≤ 5 × 10<sup>-11</sup> g / s (S)<br/> Linear dynamic range: ≥ 10<sup>3</sup> (P), ≥ 10<sup>2</sup> (S)<br/> Drift: ≤ 4 × 10<sup>-11</sup> A / 30 min<br/> Noise: ≤ 2 × 10<sup>-12</sup> A
Maximum using temperature: 250 °C<br/> Minimum LOD: < 4 pg S / sec, < 1 pg P/sec<br> Linear dynamic range: > 10<sup>3</sup> (S), > 10<sup>4</sup> (P)<br/> Optional: 10<sup>5</sup> g S / g C, 10<sup>6</sup> g P / g C
ECD
▾
Maximum temperature control: 350 °C<br/> LOD: ≤ 1 × 10<sup>-14</sup> g / ml (y - 666)<br/> Linear dynamic range: ≥ 10<sup>4</sup> <br/> Drift: ≤ 5 µV / 30 min<br/> Noise: ≤ 20 µA
Maximum using temperature: 400 °C<br/> Type of gas compensation detector: 5 % methane, argon, nitrogen<br/> Minimum LOD: > 10<sup>7</sup> S, > 10<sup>7</sup> P<br/> Linear dynamic range: 5 × 10<sup>5</sup> <br/> Data collection frequency: Maximum 100 Hz<br/> Radioactive source: < 12 mCi 63 Ni
NPD
▾
Maximum temperature control: 400 °C<br/> LOD: ≤ 5 × 10<sup>-13</sup> g / s (P), ≤ 1 × 10<sup>12</sup> g / s (N)<br> Linear dynamic range: ≥ 10<sup>3</sup> (P), ≥ 10<sup>3</sup> (N)<br/> Drift: ≤ 2.5 × 10<sup>-12</sup>A / 30 min<br/> Noise: ≤ 4 × 10<sup>-13</sup> A
Maximum using temperature: 450 °C<br/> Minimum LOD: < 0.2 pg N / sec, < 0.2 pg P / sec<br> Minimum LOQ: < 3 pg / sec<br/> Linear dynamic range: 10<sup>5</sup> N, 10<sup>5</sup> P
PDHID
▾
LOD: ≤ 5 ppb
The longest method run time
▾
999.99 min
Heating area
▾
Six individual controlling heating areas<br/> Maximum temperature in auxiliary heating area: 300 °C
Ion Chromatographic Pump
▾
a:6:{s:4:"Type";s:64:"High pressure and low pulse double plunger tandem advection pump";s:16:"Maximum pressure";s:13:"35 MPa (PEEK)";s:25:"Pressure display accuracy";s:11:"≤ 0.1 MPa";s:14:"Flow stability";s:91:"(0.2 to 0.5) ml/ min ≤ 3 %<br/> (0.5 to 1.0) ml/ min ≤ 2 %<br/> > 1.0 ml/ min 2 %<br/>";s:10:"Flow range";s:22:"0.001 to 9.999 ml/ min";s:14:"Pressure pulse";s:8:"≤ 0.5%";}
a:6:{s:4:"Type";s:64:"High pressure and low pulse double plunger tandem advection pump";s:16:"Maximum pressure";s:13:"35 MPa (PEEK)";s:25:"Pressure display accuracy";s:11:"≤ 0.1 MPa";s:14:"Flow stability";s:86:"(0.2 to 0.5) ml/ min ≤ 3 %<br/> (0.5 to 1.0) ml/ min ≤ 2 %<br/> > 1.0 ml/ min 2 %";s:10:"Flow range";s:22:"0.001 to 9.999 ml/ min";s:14:"Pressure pulse";s:8:"≤ 0.5%";}
Conductivity detector
▾
a:16:{s:4:"Type";s:53:"Temperature Control and Bipolar Conductivity Detector";s:14:"Detection mode";s:30:"Bipolar conductivity detection";s:11:"Cell volume";s:11:"≤ 0.8 µL";s:15:"Detection range";s:18:"0 to 35000 µS/ cm";s:20:"Detection resolution";s:17:"≤ 0.0020 nS/ cm";s:14:"Output voltage";s:31:"- 6000 to +6000 mV (adjustable)";s:14:"Baseline noise";s:15:"≤ 0.05 % F.S.";s:14:"Baseline drift";s:18:"≤ 3 % FS/ 30 min";s:27:"Operating temperature range";s:43:"Room temperature +5 to 60°C (41 to 140°F)";s:32:"Controlling temperature accuracy";s:10:"± 0.01°C";s:16:"Maximum pressure";s:6:"10 MPa";s:12:"Linear range";s:7:"≥ 103";s:21:"Instruments linearity";s:9:"≥ 0.999";s:26:"Quantitative repeatability";s:9:"≤ 1.0 %";s:25:"Qualitative repeatability";s:9:"≤ 1.0 %";s:32:"Minimum detectable concentration";s:73:"Cl ≤ 0.0005 ug/ ml<br/> BrO3 ≤ 0.001 ug/ ml<br/> Li+ ≤ 0.001 ug/ ml";}
a:16:{s:4:"Type";s:53:"Temperature Control and Bipolar Conductivity Detector";s:14:"Detection mode";s:30:"Bipolar conductivity detection";s:11:"Cell volume";s:11:"≤ 0.8 µL";s:15:"Detection range";s:18:"0 to 45000 µS/ cm";s:20:"Detection resolution";s:17:"≤ 0.0020 nS/ cm";s:14:"Output voltage";s:31:"- 6000 to +6000 mV (adjustable)";s:14:"Baseline noise";s:15:"≤ 0.05 % F.S.";s:14:"Baseline drift";s:18:"≤ 3 % FS/ 30 min";s:27:"Operating temperature range";s:43:"Room temperature +5 to 60°C (41 to 140°F)";s:32:"Controlling temperature accuracy";s:10:"± 0.01°C";s:16:"Maximum pressure";s:6:"10 MPa";s:12:"Linear range";s:7:"≥ 103";s:21:"Instruments linearity";s:9:"≥ 0.999";s:26:"Quantitative repeatability";s:9:"≤ 1.0 %";s:25:"Qualitative repeatability";s:9:"≤ 1.0 %";s:32:"Minimum detectable concentration";s:73:"Cl ≤ 0.0005 ug/ ml<br/> BrO3 ≤ 0.001 ug/ ml<br/> Li+ ≤ 0.001 ug/ ml";}
Flow system
▾
a:2:{s:17:"Plastic flow path";s:22:"Made of PEEK materials";s:13:"Six way Valve";s:84:"PEEK material, 5000 psi pressure, independent automatic collection and flow function";}
Degassing Device
▾
a:5:{s:12:"Inner volume";s:7:"300 µl";s:16:"Degassing volume";s:6:"7.5 ml";s:17:"Maximum flow rate";s:10:"10 ml/ min";s:20:"Degassing efficiency";s:26:"Degassing 90 % at 1ml/ min";s:17:"Organic tolerance";s:1:"1";}
Built-in Eluent Generator
▾
a:6:{s:12:"Eluent types";s:9:"KOH/ NaOH";s:26:"Eluent concentration range";s:13:"0.1 to 100 mM";s:23:"Concentration increment";s:6:"0.1 mM";s:16:"Flow rate change";s:18:"0.1 to 3.0 ml/ min";s:16:"Maximum pressure";s:6:"20 MPa";s:16:"Minimum pressure";s:5:"5 MPa";}
Power supply
▾
150 W
External dimension
▾
350 × 470 × 650 mm
350 × 470 × 510 mm
Net weight
▾
34 kg
26 kg
Gross weight
▾
40 kg
32 kg
Temperature Range
▾
RT to 450 °C
Temperature Accuracy
▾
≤ ± 0.1℃
Temperature Program
▾
16-phase
Maximum Temperature Heating Rate
▾
40℃/min
Detector
▾
Hydrogen Flame Ionization Detector (FID)
Detection Limit
▾
≤ 3×10⁻¹²g/s (Sample: n-hexadecane)
Baseline Drift
▾
≤ 1×10⁻¹³A/30min
Linear Range
▾
≥ 10⁷
Capillary Columns
▾
0.32 mm Ø, 80 m length
Display
▾
5.7-inch LCD
Power
▾
AC220V±10%, 50/60Hz
Oven Dimensions
▾
300 × 280 ×180 mm
Dimensions
▾
820 × 670 × 600mm
Weight
▾
71kg
Price Range
Select Price Range
Up to $500
$501 - $1000
$1001 - $5000
$5001 - $10000
$10001 and above
Chromatography
Gas Chromatography
Ion Chromatography
Gas Chromatograph Mass Spectrometer