Nano spectrophotometer
Nano Spectrophotometer 15A-NSP100
Wavelength range : 200 - 800 nm
Path length : 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Wavelength accuracy : ± 1 nm
Wavelength Resolution : ≤ 3 nm (FWHM at Hg 546 nm)
Path length : 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Wavelength accuracy : ± 1 nm
Wavelength Resolution : ≤ 3 nm (FWHM at Hg 546 nm)
Nano Spectrophotometer 15A-NSP101
Wavelength range : 200 - 850 nm
Path length : 1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy : ± 1 nm
Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
Path length : 1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy : ± 1 nm
Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
Nano Spectrophotometer 15A-NSP102
Wavelength range : 200 - 850 nm
Path length : 1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy : ± 1 nm
Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
Path length : 1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy : ± 1 nm
Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
Nano Spectrophotometer 15A-NSP200
Wavelength range : 230 nm, 260 nm, 280 nm
Path length : 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Minimum Sample size : 0.5 - 2.0 µl
Absorbance range : 0.02 - 80 A (10mm equivalent)
Path length : 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Minimum Sample size : 0.5 - 2.0 µl
Absorbance range : 0.02 - 80 A (10mm equivalent)
Nano Spectrophotometer 15A-NSP201
Wavelength range : 230 nm, 260 nm, 280 nm
Path length : 1.0 mm, 0.2 mm
Minimum Sample size : 0.3 - 2.0 µl
Absorbance range : 0.2 - 75A (10 mm equivalent absorbance)
Path length : 1.0 mm, 0.2 mm
Minimum Sample size : 0.3 - 2.0 µl
Absorbance range : 0.2 - 75A (10 mm equivalent absorbance)
Nano Spectrophotometer 15A-NSP300
Cuvette : No
PC : Inbuilt
Wavelength range : 190 - 850 nm
Path length : 1 mm, 0.2 mm ,0.04 mm
PC : Inbuilt
Wavelength range : 190 - 850 nm
Path length : 1 mm, 0.2 mm ,0.04 mm
Nano Spectrophotometer 15A-NSP301
Cuvette : Yes
PC : Inbuilt
Wavelength range : 190 - 850 nm
Path length : 1 mm, 0.2 mm ,0.04 mm
PC : Inbuilt
Wavelength range : 190 - 850 nm
Path length : 1 mm, 0.2 mm ,0.04 mm
Nano Spectrophotometer 15A-NSP302
Cuvette : Yes
Temperature : Room Temperature 42 ºC
PC : Inbuilt
Wavelength range : 190 - 850 nm
Temperature : Room Temperature 42 ºC
PC : Inbuilt
Wavelength range : 190 - 850 nm
Nano Spectrophotometer 15A-NSP303
Cuvette : Yes
Temperature : 4 ºC - 42 ºC (Heating & Cooling)
PC : Inbuilt
Wavelength range : 190 - 850 nm
Temperature : 4 ºC - 42 ºC (Heating & Cooling)
PC : Inbuilt
Wavelength range : 190 - 850 nm