Sample capacity : 1 standard block
Heating speed : ≤ 30 min ( 20 °C ~ 150 °C )
Temperature display accuracy : 0.1 °C
Time range : 1 min ~ 99h 59 mins or continuous

Sample capacity : 2 standard block
Heating speed : ≤ 30 min ( 20 °C ~ 150 °C )
Temperature display accuracy : 0.1 °C
Time range : 1 min ~ 99h 59 mins or continuous

Sample capacity : 2 block individual control
Heating speed : ≤ 30 min ( 20 °C ~ 150 °C )
Temperature display accuracy : 0.1 °C
Time range : 1 min ~ 99h 59 mins or continuous

Sample capacity : 4 standard blocks
Heating speed : ≤ 30 min ( 20 °C ~ 120 °C )
Temperature display accuracy : 0.1 °C
Time range : 1 min ~ 99h 59 mins or continuous

Heating speed : ≤ 15 min ( 20 °C ~ 100 °C )
Temperature display accuracy : 0.1 °C
Time range : 1 min ~ 99h 59 mins or continuous
Temperature control range : RT 5 °C to 150 °C

Heating speed : ≤ 15 min ( 20 °C ~ 100 °C )
Cooling speed : ≤ 30 min ( RT decreases 30 °C ) at RT 26 °C
Temperature display accuracy : 0.1 °C
Time range : 1 min ~ 99 h 59 mins or continuous

Heating mode : Dual heating
Temperature control range : RT 5 ˚C ~ 100 ˚C
Temperature setting range : 5 ˚C ~ 100 ˚C
Temperature display accuracy : 0.1 °C

Heating mode : Dual cooling
Temperature control range : -10 ˚C ~ 100 ˚C
Temperature setting range : -10 ˚C ~ 100 ˚C
Temperature maximum decrease : RT decreases 20 ˚C

Heating mode : Heating-cooling mixing
Temperature control range : Heating : RT 5 ˚C ~ 100 ˚C ; Cooling : ( - 10 ˚C ~ 100 ˚C )
Temperature setting range : 5 ˚C ~ 105 ˚C / -10 ˚C ~ 100 ˚C
Temperature maximum decrease : RT decreases 20 ˚C

Fan speed range : 1200 ~ 3200 rpm
Incubation space size ( W x D x H ) : 215 × 245 × 85 mm
Temperature display accuracy : 0.1 °C
Time range : 1 min ~ 99 h 59 mins

Sample capacity : 2 pieces of plates ( Height < 40 mm )
Heating speed : ≤ 25 mins (20˚C to 70˚C)
Platform temperature uniformity : ± 0.5 ˚C
Temperature display accuracy : 0.1 ˚C

Sample capacity : 4 pieces of plates ( Height < 40 mm )
Heating speed : ≤ 25 mins ( 20 ˚C to 70 ˚C )
Platform temperature uniformity : ± 0.5 ˚C
Temperature display accuracy : 0.1 ˚C

Speed range : 300 ~ 1200 rpm
Shaking orbit : 3 mm ( horizontal )
Sample capacity : 2 pieces of plates ( Height < 40 mm )
Platform temperature uniformity : ≤ ± 0.5 °C

Speed range : 300 ~ 1200 rpm
Shaking orbit : 2 mm ( horizontal )
Sample capacity : 4 pieces of plates ( Height < 40 mm )
Platform temperature uniformity : ≤ ± 0.5 °C

Speed range : 300 ~ 2000 rpm
Shaking orbit : 3 mm ( horizontal )
Temperature control range : RT 5 °C to 100 °C
Temperature setting range : 5 °C ~ 100 °C

Speed range : 300 ~ 1500 rpm
Shaking orbit : 3 mm ( horizontal )
Temperature control range : 0 °C to 100 °C
Temperature setting range : 0 °C ~ 100 °C